Current Sensing Relay AC Current Sensing Switch 0-30A Normally Open Current Sensor Monitoring Relay (M3050)
Thumbnail 1Thumbnail 2Thumbnail 3Thumbnail 4Thumbnail 5Thumbnail 6Thumbnail 7Thumbnail 8Thumbnail 9

Current Sensing Relay AC Current Sensing Switch 0-30A Normally Open Current Sensor Monitoring Relay (M3050)

4.2/5
Product ID: 475614730
Secure Transaction
⚡0-30A AC Input
🔄Millisecond Response
🛡️2000V Isolation
Frequently Bought Together

Description

🔌 Power Up Your Monitoring Game!

  • DURABLE BUILD - Constructed with high-impact ABS material for long-lasting performance.
  • INSTANT FEEDBACK - LED indicators provide real-time status updates for seamless operation.
  • PRECISION CONTROL - Achieve accurate AC current monitoring with ease.
  • UNLIMITED OPERATIONS - No limits on opening and closing cycles, ensuring reliability in demanding environments.
  • COST EFFECTIVE DESIGN - Simplify your setup and reduce expenses compared to traditional methods.

The M-3050 AC Current Sensing Relay is a cutting-edge solution for monitoring AC current from 0-30A. It features a self-powered design, high-speed response, and robust isolation capabilities, making it ideal for controlling automated industrial equipment with precision and reliability.

Large manufacture image 1
Small manufacture image 1Small manufacture image 2Small manufacture image 3Small manufacture image 4

Have a Question? See What Others Asked

3 hp 220v pool motor with internal timer. when the motor is on i want a small 120v motor to operate. big motor off -small motor off, recommendations?
What does "contact capacity of the switch 0.3 a @240v" mean? i need to run a 110v 3/4 hp motor based on whether or not a 3 hp 240 v. is running

Reviews

4.2

All from verified purchases

R**N

Awesome!

Works as advertised and is small (doesn't take up space). I wanted to detect each time a pump ran which then went to a totalizer/counter. Worked perfectly!

M**C

Works with both 120V and 220V

The media could not be loaded. This is a fantastic relay!I am going to use it to prevent power from flowing to my pool's booster pump when the main pump is not operating. When this relay senses power flowing to the main pump, it will trigger a second relay that will allow the booster pump to run.I need the second relay because this relay cannot handle a load exceeded 0.3 amps and my booster pump draws 4.5 amps.I put together a testbed based on 120V to verify that it works as described, and indeed it does:1. It is described as "self-powered" and that is consistent with my experience. I assume it is inductively drawing a small amount of power from the current it is sensing and uses that to power the LEDs.2. The threshold setting works as expected. I tested with a 3-speed, 20" box fan. I was able to adjust the sensitivity such that the relay was "off" when the fan was on low and "on" when the fan was on medium.The video demonstrates all of this with nothing attached to K1 and K2. I also ran a test with a 120V, 8 watt LED bulb connected between K1 and K2. The bulb turned on and off at the appropriate times.Highly recommended!

J**D

Defective

I tried M3066 and M3056 at various amperages @ 120V, and the relay never changed.I varied the amperage from .3A to 13A, and no change in either current switch.The adjustment screw was turned each way with no results.The 3066 stayed open and the 3056 stayed closed.

M**W

It works well

The media could not be loaded. I realize I bought the wrong one, but it still does what it is supposed to do. I would have been nice it it had both a normality open and a normal closed connection that way it will ether one. Its activation current is adjustable as it says. The LEDs light up as long as there is a current flowing through the wire. It is meant for sensing a circuit that alway has current flowing the it. This way it will change when the current goes above the threshold that is set by the technician/user.

T**H

Seems to work reliably in limited use so far. I could not seem to adjust it to a very low current

I bought this to control a load share contactor. I wanted a 50A unit so I could change to a high current threshold if needed later although it would normally be run well below this level. I was easily able to adjust threshold to below 24A where it would normally be used but could not get it as low as 5A. I did not investigate minimum levels further.The LEDS make it easy to use and I could drive the contacter coil directly whiich is very helpful.One iissue is the device does not have any hysteresis built in, this means if operating is around the threshold current it can cause the contactor relay to chatter rather than switching positively. Depending on application this may wear out the contactor or relay prematurely and may not be good for the load either.

P**T

great all in one sensor

Great little device! I bought 5 of these to automate the opening of my blast gates when a power tool turns on in my home workshop. One of 5 did not work; it was replaced the next day. Now they all operate as expected and I am a happy wood worker.

G**R

Worked great in a circuit on my ESP8266

Worked perfect for current sensing logic on my ESP8266. Adjustable trigger point. (They give you a tiny screwdriver for adjusting it.) Self powered LEDs. A couple mounting screws, and a manual showing wiring diagrams for several different applications. Yeah!

C**K

Works well

It was easy to install. I use it to monitor if my spa heater is running.

Common Questions

Trustpilot

TrustScore 4.5 | 7,300+ reviews

Ali H.

Fast shipping and excellent packaging. The Leatherman tool feels very premium and sturdy.

1 day ago

Imran F.

Very reliable shop with genuine products. Will definitely buy again!

2 weeks ago

Shop Global, Save with Desertcart
Value for Money
Competitive prices on a vast range of products
Shop Globally
Serving over 300 million shoppers across more than 200 countries
Enhanced Protection
Trusted payment options loved by worldwide shoppers
Customer Assurance
Trusted payment options loved by worldwide shoppers.
Desertcart App
Shop on the go, anytime, anywhere.
JD 35.54

Duties & taxes incl.

JORDANstore
1
Free Returns

30 daysfor PRO membership users

15 dayswithout membership

Secure Transaction

Trustpilot

TrustScore 4.5 | 7,300+ reviews

Anjali K.

The product quality is outstanding. Exactly what I needed for my work.

1 month ago

Ayesha M.

The product exactly matches the description. Very satisfied with my purchase.

5 days ago

Current Sensing Relay Ac Current Sensing Switch 0 30a Normally | Desertcart JORDAN